DocumentCode
1958492
Title
Contrast-enhanced intravascular ultrasound 3D reconstruction of a vasa vasorum mimicking model
Author
Maresca, David ; Emmer, Marcia ; Springeling, Geert ; Mastik, Frits ; Van Soest, Gijs ; De Jong, Nico ; Van der Steen, Antonius F W
Author_Institution
Dept. of Biomed. Eng., Erasmus MC, Rotterdam, Netherlands
fYear
2010
fDate
11-14 Oct. 2010
Firstpage
2364
Lastpage
2367
Abstract
It is increasingly recognized that the development of new microvessels (vasa vasorum) within and surrounding atherosclerotic plaques is essential to enable artery lesion growth and plays a central role in rendering it vulnerable to rupture. Currently, there is no established clinical technique capable of imaging the vasa vasorum (VV) in the coronary arteries of humans. It has been shown that contrast-enhanced intravascular ultrasound (CE-IVUS) is capable of imaging VV in vivo. This study aims at reconstructing in three dimensions (3D) a VV model using CE-IVUS with a clinical coronary imaging catheter. A polyvinyl alcohol based VV model was manufactured, exhibiting a VV mimicking branch pattern with a diameter ranging from 200 to 100 μm. After perfusion of the VV model with the ultrasound contrast agent Definity®, a manual pullback consisting of 93 cross sectional IVUS images spaced every 200 μm was performed. Perfused areas were segmented in two registered CE-IVUS planes and compared to coregistered 10 μm thick slices of the VV model. The VV mimicking microchannel diameters measured with CE-IVUS agreed within 30% with the slice diameters. As CE-IVUS imaging can be carried out in-vivo, this method could be used during clinical IVUS investigations as an additional diagnostic for plaque vulnerability.
Keywords
biomedical ultrasonics; blood vessels; cardiology; catheters; haemorheology; image reconstruction; image segmentation; medical image processing; VV mimicking branch pattern; VV mimicking microchannel diameter measurement; artery lesion growth; atherosclerotic plaques; clinical IVUS investigations; clinical coronary imaging catheter; clinical technique; contrast-enhanced intravascular ultrasound 3D reconstruction; coronary arteries; imaging VV in vivo; microvessels; perfusion; plaque vulnerability; polyvinyl alcohol based VV model; rupture; size 10 mum; ultrasound contrast agent; vasa vasorum mimicking model; Acoustics; Arteries; Microchannel; Phantoms; Three dimensional displays; Ultrasonic imaging; 3D reconstruction; intravascular ultrasound; ultrasound contrast agent; vasa vasorum;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2010 IEEE
Conference_Location
San Diego, CA
ISSN
1948-5719
Print_ISBN
978-1-4577-0382-9
Type
conf
DOI
10.1109/ULTSYM.2010.5935756
Filename
5935756
Link To Document