• DocumentCode
    1961162
  • Title

    Transverse oscillations for phased array vector velocity imaging

  • Author

    Pihl, Michael Johannes ; Jensen, Jørgen Arendt

  • Author_Institution
    Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
  • fYear
    2010
  • fDate
    11-14 Oct. 2010
  • Firstpage
    1323
  • Lastpage
    1327
  • Abstract
    Medical ultrasound imaging is widely used to visualize blood flow in the human circulatory system. However, conventional methods are angle dependent. The Transverse Oscillation (TO) method is able to measure the lateral velocity component, and it has been demonstrated in in vivo measurements of superficial blood vessels. To broaden the usability of the method, it should be expanded to a phased array geometry enabling vector velocity imaging of the heart. Therefore, the scan depth has to be increased to 10-15 cm. This paper presents suitable pulse echo fields (PEΓ). Two lines are beamformed in receive to obtain lateral spatial in-phase and quadrature components. The relative mean bias and standard deviation of the lateral velocity component are computed as performance measures. For the PEF, the coefficient of variance, CV, of the spectral frequencies, and the energy ratio, ER, of leakage into negative frequencies are used as metrics to assess estimator performance. At 10 em´s depth for an initial setup, the relative mean bias and standard deviation are 9.1% and 9.5%, respectively. At a depth of 15 cm, the values are 20% and 13%, respectively. The PEF metric ER can be used to assess the bias (correlation coefficient, R: -0.76), and therefore predict estimator performance. CV is correlated with the standard deviation (R=0.74). The results demonstrate the potential for using a phased array for vector velocity imaging at larger depths, and potentially for imaging the heart.
  • Keywords
    biomedical ultrasonics; blood flow measurement; blood vessels; cardiology; oscillations; PEF metric ER; beamforming; blood flow measurement; estimator performance; heart; in-vivo measurement; lateral spatial in-phase components; medical ultrasound imaging; phased array geometry; phased array vector velocity imaging; pulse echo fields; quadrature components; standard deviation; superficial blood vessels; transverse oscillation method; Arrays; Blood; Erbium; Estimation; Imaging; Measurement; Oscillators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2010 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-0382-9
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2010.5935879
  • Filename
    5935879