Theoretical and experimental study of fluid behavior of a peristaltic micropump
Author
Na, Sangkwon ; Ridgeway, Shane ; Li Cao
Author_Institution
Dept. of Mech. Eng., Iowa State Univ., Ames, IA, USA
fYear
2003
fDate
30 June-2 July 2003
Firstpage
312
Lastpage
316
Abstract
An embedded PZT actuated peristaltic micropump that is a part of an implantable medical drug delivery system was designed and fabricated using Microelectromechanical Systems (MEMS) technology. Three embedded PZT actuators drive the three micropump chambers in a peristaltic motion. Static deflection data of the micropump chamber actuated by the PZT was measured using Atomic Force Microscope (AFM). The deflection data are linear below 90 volts and initiate a slightly non-linear behavior above 90 volts to 130 volts that is the maximum voltage we drive our micropump. In order to obtain linear response between driving voltage and pumping performance, it is recommended to drive the embedded PZT to actuate the peristaltic micropump below 90 volts. Volumetric flow rate and maximum pumping pressure data of the peristaltic micropump for four different driving frequencies (0.5 Hz, 1 Hz, 2 Hz, and 4 Hz) at 90 volts were tested. Volumetric flow rate and maximum pumping pressure data of the peristaltic micropump for four different driving frequencies (0.5 Hz, 1 Hz, 2 Hz, and 4 Hz) at 130 volts were tested. The overall efficiency of the micropump for two driving voltages (90 volts and 130 volts) was calculated. For a volumetric flowrate of 6 μL/min, the overall efficiency for the micropump driven at 90 volts was achieved at 0.015%. If our desired volumetric flowrate of the micropump is 10 μL/min, the overall efficiency for the micropump driven at 90 volts will be even lower. This low overall efficiency tendency for the micropump is due to the more input power to increase the pumping performance. For the same volumetric flowrate of 6 μL/min, the overall efficiency for the micropump driven at 130 volts was achieved at 0.060%, which is four times of the overall efficiency for the micropump driven at 90 volts. To improve the overall efficiency for the micropump that is for implanted) medical drug delivery systems, we recommend driving the micropump at a higher voltage than 90 volts. A theoretical model of the fluid behavior of the micropump was also developed with the assumption that the peristaltic micropump is working in a steady state flow. The fluid static behaviors (deflection, flowrate, and pumping pressure) from this model were compared with our expe- riment data. The experimental data meet with our theoretical model well.
Keywords
atomic force microscopy; drug delivery systems; flow simulation; lead compounds; micropumps; peristaltic flow; piezoelectric actuators; prosthetics; 0.5 Hz; 1 Hz; 130 V; 2 Hz; 4 Hz; AFM; MEMS; PZT; PZT actuator; PbZrO3TiO3; atomic force microscopy; fluid behavior; implantable medical drug delivery system; microelectromechanical systems; numerical simulations; peristaltic micropump; static deflection; steady state flow; volumetric flowrate; Atomic force microscopy; Atomic measurements; Drug delivery; Force measurement; Frequency; Microelectromechanical systems; Micromechanical devices; Micropumps; Testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
University/Government/Industry Microelectronics Symposium, 2003. Proceedings of the 15th Biennial
ISSN
0749-6877
Print_ISBN
0-7803-7972-1
Type
conf
DOI
10.1109/UGIM.2003.1225751
Filename
1225751
Link To Document