• DocumentCode
    1962847
  • Title

    Phasing schemes for the CEBAF cavities

  • Author

    Simrock, S.N. ; Kazimi, R. ; Krafft, G.A. ; Menninga, L. ; Ninan, L. ; Witherspoon, S.

  • Author_Institution
    Continuous Electron Beam Accel. Facility, Newport News, VA, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    599
  • Abstract
    The CEBAF accelerator requires accurate phasing of the 338 superconducting cavities to achieve the design rms energy spread of 2.5·10-5. The rms phase error along each linac, with 160 cavities over a length of 200 m, may not exceed 2.6°, assuming that the whole linac is operated on crest. The common procedure is to maximize the energy gain with a spectrometer. At CEBAF, however, phase-dependent cavity steering effects cause deflections of the beam of several mrad, requiring steering corrections in the linac, which makes this method very time consuming. Beam-induced transients can also be used in pulsed operation to determine the zero-energy-gain phase with high accuracy. Better than 2° accuracy is achieved when the signal-to-noise ratio is improved by signal averaging. These and other approaches for the phasing of cavities are compared and accuracy and feasibility are discussed
  • Keywords
    beam handling techniques; electron accelerators; linear accelerators; CEBAF cavities; RMS energy spread; RMS phase error; beam-induced transients; phase-dependent cavity steering effects; phasing schemes; steering corrections; superconducting cavities; Acceleration; Electric shock; Electron accelerators; Electron beams; Linear particle accelerator; Phase measurement; Radio frequency; Signal to noise ratio; Spectroscopy; Stability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.308795
  • Filename
    308795