Title :
Stability of beam in the Fermilab Main Injector
Author :
Mishra, C.S. ; Harfoush, F.A.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
The Fermilab Main Injector is a new 150 GeV proton synchrotron, designed to remove the limitations of the Main Ring in the delivery of high intensity proton and antiproton beams to the Tevatron. Extensive studies has been made to understand the performance of the Main Injector. In this paper, we present a study of the Main Injector lattice, which includes magnetic and misalignment errors. These calculations shows the Main Injector´s dynamical aperture is larger than its design value of 40 π mm mradian at injection
Keywords :
beam handling techniques; particle beam diagnostics; proton accelerators; synchrotrons; 150 GeV; Fermilab Main Injector; Main Injector lattice; Tevatron; beam stability; dynamical aperture; high intensity antiproton beams; high intensity proton beams; magnetic errors; misalignment errors; proton synchrotron; Apertures; Extraterrestrial measurements; Lattices; Magnetic field measurement; Magnets; Orbital calculations; Proton accelerators; Radio frequency; Saturation magnetization; Stability;
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
DOI :
10.1109/PAC.1993.308918