• DocumentCode
    1965733
  • Title

    The influence of high-voltage and coal dust particle size distribution on dust collecting efficiency

  • Author

    Zhang, Zi-sheng ; Liu, Qiang ; Xiao, Zhen-lei ; Zhang, Bo ; Yang, Zhen-ya ; Liu, Zhi-qiang ; Li, Qing

  • Author_Institution
    Electrostatic Res. Inst., Hebei Univ., Baoding, China
  • Volume
    2
  • fYear
    2010
  • fDate
    10-11 July 2010
  • Firstpage
    148
  • Lastpage
    151
  • Abstract
    The working efficiency of electrostatic precipitator can be affected by many factors, and the dust particle size is one of the important factors. The coal dust is used to subject investigated in this test, Dust particle size distribution is tested through experiment combining the theories foundation of the dust particle charge, and the relation between the size of the coal dust particle and the dust collecting efficiency of electrostatic precipitator is analyzed. When electric-field intensity is 32.857 kV and 60 kV, dust collecting efficiency with augment of dust particle size first increase then reduce, but when electric-field intensity is 30 kV, particle size has little effect on dust collecting efficiency. While particle size is 300.0-109.0 μm, dust collecting efficiency is steady when the electric fields have the same intensity.
  • Keywords
    coal; dust; electrostatic precipitators; particle size; coal dust; dust collecting efficiency; dust particle size distribution; electric fields; electrostatic precipitator; size 300.0 mum to 109.0 mum; voltage 30 kV; voltage 32.857 kV; voltage 60 kV; Electrostatics; High-voltage; coal dust particle size; dust collecting efficiency; electrostatic precipitator; particle charge;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial and Information Systems (IIS), 2010 2nd International Conference on
  • Conference_Location
    Dalian
  • Print_ISBN
    978-1-4244-7860-6
  • Type

    conf

  • DOI
    10.1109/INDUSIS.2010.5565657
  • Filename
    5565657