DocumentCode
1965733
Title
The influence of high-voltage and coal dust particle size distribution on dust collecting efficiency
Author
Zhang, Zi-sheng ; Liu, Qiang ; Xiao, Zhen-lei ; Zhang, Bo ; Yang, Zhen-ya ; Liu, Zhi-qiang ; Li, Qing
Author_Institution
Electrostatic Res. Inst., Hebei Univ., Baoding, China
Volume
2
fYear
2010
fDate
10-11 July 2010
Firstpage
148
Lastpage
151
Abstract
The working efficiency of electrostatic precipitator can be affected by many factors, and the dust particle size is one of the important factors. The coal dust is used to subject investigated in this test, Dust particle size distribution is tested through experiment combining the theories foundation of the dust particle charge, and the relation between the size of the coal dust particle and the dust collecting efficiency of electrostatic precipitator is analyzed. When electric-field intensity is 32.857 kV and 60 kV, dust collecting efficiency with augment of dust particle size first increase then reduce, but when electric-field intensity is 30 kV, particle size has little effect on dust collecting efficiency. While particle size is 300.0-109.0 μm, dust collecting efficiency is steady when the electric fields have the same intensity.
Keywords
coal; dust; electrostatic precipitators; particle size; coal dust; dust collecting efficiency; dust particle size distribution; electric fields; electrostatic precipitator; size 300.0 mum to 109.0 mum; voltage 30 kV; voltage 32.857 kV; voltage 60 kV; Electrostatics; High-voltage; coal dust particle size; dust collecting efficiency; electrostatic precipitator; particle charge;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial and Information Systems (IIS), 2010 2nd International Conference on
Conference_Location
Dalian
Print_ISBN
978-1-4244-7860-6
Type
conf
DOI
10.1109/INDUSIS.2010.5565657
Filename
5565657