Title :
Fixed target to collider changeover at A0 [Fermilab accelerator]
Author :
Weber, Katharine J.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
The A0 sector of the Main Accelerator at Fermilab serves a dual function. During a collider run this sector is used as an abort. The same area is used to divert beam to the switchyard during a fixed target run. The area is subject to high residual radiation, therefore making it important that personnel working to change the equipment do so with a minimal amount of radiation exposure. A system has been designed to reduce the time a technician must spend in this area
Keywords :
proton accelerators; radiation protection; storage rings; synchrotrons; A0 sector; Fermilab; Main Accelerator; collider experiments; fixed target experiments; radiation exposure; radiation safety; Acceleration; Colliding beam accelerators; Concrete; Floors; Hardware; Magnets; Physics; Protons; Steel; Structural beams;
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
DOI :
10.1109/PAC.1993.309049