Title :
Design and operation of the HIMAC injector
Author :
Murakami, Takeshi ; Ogawa, Hirotsugu ; Yamada, Satoru ; Sato, Yukio ; Yamada, Takanobu ; Kitagawa, Atsushi ; Yoshizawa, Jun ; Fu, Shinian ; Kohno, Toshiyuki ; Sato, Kenji ; Itano, Akifumi ; Kumada, Masayuki ; Takada, Eiichi ; Kanazawa, Mitsutaka ; Noda, K
Author_Institution :
Nat. Inst. of Radiol. Sci., Chiba, Japan
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
1686
Abstract :
A heavy-ion synchrotron dedicated to medical use is under construction at the National Institute of Radiological Sciences, Japan. The injector system, comprising a PIG source, an ECR source, an RFQ linac, and an Alvarez linac of 100 MHz, accelerates heavy ions with a charge-to-mass ratio as small as 1/7, up to 6 MeV/nucleon. First operation of the injector system has shown satisfactory performance
Keywords :
beam handling techniques; biomedical equipment; ion accelerators; synchrotrons; 100 MHz; Alvarez linac; ECR source; HIMAC; PIG source; RFQ linac; design; injector; operation; Acceleration; Construction industry; Ion accelerators; Ion sources; Linear particle accelerator; Medical diagnostic imaging; Particle beams; Structural beams; Synchrotrons; Voltage;