  • Abstract
    The Advanced Light Source (ALS), a third generation synchrotron radiation facility, is complete. The particle beam diagnostics have been installed and tested. The beam injection systems have been running for two years. We have performance data on beam position monitors, beam intensity monitors, scintillators, beam collimators, a 50 Ω Faraday cup, and broad-band striplines and kickers used in the linac, transport lines, and the booster synchrotron. The single-turn monitoring capability of the booster beam position monitoring system has been particularly useful for studying beam dynamics. Beam diagnostics for the storage ring are being commissioned. In this paper we describe each instrument, show its performance, and outline how the instruments are controlled and their output data displayed
  • Keywords
    electron accelerators; particle beam diagnostics; storage rings; 50 ohm; ALS; Advanced Light Source; Faraday cup; beam collimators; beam intensity monitors; beam position monitors; booster beam position monitoring system; broad-band striplines; kickers; particle beam diagnostics; scintillators; Collimators; Instruments; Light sources; Linear particle accelerator; Monitoring; Particle beam injection; Particle beams; Stripline; Synchrotron radiation; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309233
  • Filename
    309233