DocumentCode :
1971696
Title :
Beam diagnostic layout requirements for SSCL linac
Author :
Hurd, J.W. ; Guy, F.W. ; Jamieson, G. ; Raparia, D. ; Saadatmand, K.
Author_Institution :
Superconducting Super Collider Lab., Dallas, TX, USA
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
2127
Abstract :
A basic set of diagnostics is needed to commission, tune, and monitor the operation of the SSCL linac. This set of diagnostics has been refined in the final stages of design of the linac. Planned diagnostics include current monitors, Faraday cups, beam loss monitors, beam position monitors, wire scanners, absorber-collector phase scan units, slit and collector emittance measurement units, and longitudinal bunch shape monitors. The diagnostics are described and their placement along the linac is given. The use of the diagnostics for tuning the linac is described. The first set of diagnostics will be installed with the RFQ, with additional diagnostics installed with each linac section
Keywords :
ion accelerators; linear accelerators; particle beam diagnostics; Faraday cups; SSC linac; beam loss monitors; beam position monitors; current monitors; diagnostics; emittance measurement; longitudinal bunch shape monitors; tuning; wire scanners; Acceleration; Colliding beam accelerators; Extraterrestrial measurements; Linear particle accelerator; Monitoring; Particle beams; Position measurement; Shape measurement; Structural beams; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
Type :
conf
DOI :
10.1109/PAC.1993.309243
Filename :
309243
Link To Document :
بازگشت