Title :
Performance of the CEBAF arc beam position monitors
Author :
Hofler, A.S. ; Bowling, B.A. ; Higgins, C.S. ; Kloeppel, P.K. ; Krafft, G.A. ; Mahoney, K.L.
Author_Institution :
Continuous Electron Beam Accel. Facility, Newport News, VA, USA
Abstract :
The first three quarters of the first CEBAF arc have been instrumented with beam position monitors. Thirty-seven monitors (of 450) have been installed and their noise measured. Resolution of 100 μm was obtained at the lowest operating current of 1 μA. The update time of the system is 1 sec, limited by computer interfacing, with a potential bandwidth of greater than 10 kHz
Keywords :
beam handling equipment; calibration; electron accelerators; linear accelerators; noise; particle beam diagnostics; physics computing; 1 muA; 1 s; CEBAF arc beam position monitors; computer interfacing; noise; operating current; potential bandwidth; resolution; update time; Calibration; Circuits; Computer displays; Electron beams; Extraterrestrial measurements; Gain measurement; Position measurement; Software measurement; Voltage; Wires;
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
DOI :
10.1109/PAC.1993.309301