Abstract :
A working prototype of beam position monitor (BPM) electronics, based on the log-ratio technique is described in this paper. Results of a test performed at the Fermilab Booster, comparing the existing Fermilab BPM system are also presented. A calibration technique has been used which corrects errors due to mismatched channels and electronics drift. The results are compared with bench measurements on the prototype circuit
Keywords :
calibration; error correction; nuclear electronics; particle beam diagnostics; position measurement; proton accelerators; storage rings; synchrotrons; Fermilab Booster; SSC log-ratio beam position monitor electronics; calibration technique; electronics drift; error correction; mismatched channels; prototype circuit; test results; working prototype; Circuit simulation; Circuit testing; Dynamic range; Electronic equipment testing; Laboratories; Monitoring; Noise figure; Noise measurement; Performance evaluation; Signal to noise ratio;