• DocumentCode
    1973690
  • Title

    Bunch shape monitor for SSCL linac

  • Author

    Hurd, J.W. ; Arbique, G.M. ; Crist, C.E. ; Guy, F.W. ; Leifeste, G.T. ; Raparia, D. ; Saadatmand, K. ; Swenson, D.A. ; Esin, S. ; Feschenko, A. ; Stepanov, A. ; Mirzojan, A.

  • Author_Institution
    Superconducting Super Collider Lab., Dallas, TX, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2426
  • Abstract
    The Superconducting Super Collider Laboratory and the Institute for Nuclear Research are collaboratively developing a Bunch Shape Monitor diagnostics for commission the SSCL linac. The Bunch Shape Monitor is designed to measure the intensity of beam as a function of time over the micro-bunch of the beam. Design resolution for the SSCL monitors is approximately 7 psec. The first monitor will operate at the fundamental frequency of 428 MHz and will be used to measure the output beam of the RFQ Linac. First available results will be presented and compared with predictions. Further development will allow the monitors to fit in a standard SSCL beam box and one will operate at the third harmonic of 428 MHz. Proposals to use the Bunch Shape Monitor to measure the longitudinal phase space distribution of the beam are discussed
  • Keywords
    beam handling techniques; linear accelerators; particle beam diagnostics; proton accelerators; 428 MHz; SSCL beam box; SSCL linac; Superconducting Super Collider Laboratory; bunch shape monitor; longitudinal phase space distribution; Collaboration; Frequency measurement; Laboratories; Linear particle accelerator; Monitoring; Particle beam measurements; Proposals; Shape measurement; Standards development; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309344
  • Filename
    309344