• DocumentCode
    1974140
  • Title

    Measurement of vertical emittance at LEP from hard X-rays

  • Author

    Akbari, H. ; Borer, J. ; Bovet, C. ; Delmere, Ch. ; Manarin, A. ; Rossa, E. ; Sillanoli, M. ; Spanggaard, J.

  • Author_Institution
    SL Div., CERN, Geneva, Switzerland
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2492
  • Abstract
    Two solid state detectors measure in real time the vertical profiles of both beams in LEP, from hard X-rays produced in normal machine dipoles. Each detector consists of 64 elements of CdTe photoconductor deposited with a pitch of 100 pm on a ceramic support. Profiles can be recorded at the rate of bunch passages (88 kHz) for 250 revolutions and are subsequently analysed. This paper describes the new readout electronics adapted to 8 bunch operation of LEP and the performance of detectors using the data acquired in 1992. From the r.m.s. size of these profiles and the knowledge of machine optics, emittance values are obtained
  • Keywords
    electron accelerators; nuclear electronics; particle beam diagnostics; storage rings; synchrotrons; CdTe photoconductor; LEP; bunch passages; ceramic support; hard X-rays; machine dipoles; readout electronics; solid state detectors; vertical emittance measurement; Ceramics; Motion detection; Photoconductivity; Positrons; Readout electronics; Stimulated emission; Synchrotrons; Testing; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309366
  • Filename
    309366