DocumentCode
1974359
Title
RF synchronous transfer into specific buckets between Fermilab Main Ring and Tevatron accelerators
Author
Meisner, K.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
2522
Abstract
I present a description of the design philosophy, hardware implementation, and operation of the system used to place beams transferred in either direction between the Main Ring and Tevatron accelerators into specified RF buckets of the receiving machine. The system provides reliable phase coordinate placement with 0.09° resolution without beam measurements of any kind. The system also controls the collision point in the Tevatron during the Fermilab colliding beams HEP program with 0.689 mm resolution
Keywords
beam handling techniques; cavity resonators; proton accelerators; synchrotrons; Fermilab Main Ring; RF buckets; RF synchronous transfer; Tevatron accelerator; colliding beams HEP program; collision point; design philosophy; hardware implementation; phase coordinate placement; Acceleration; Colliding beam accelerators; Control systems; Forging; Frequency modulation; Frequency synchronization; Oscillators; Particle beam injection; Particle beams; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309376
Filename
309376
Link To Document