  • Abstract
    I present a description of the design philosophy, hardware implementation, and operation of the system used to place beams transferred in either direction between the Main Ring and Tevatron accelerators into specified RF buckets of the receiving machine. The system provides reliable phase coordinate placement with 0.09° resolution without beam measurements of any kind. The system also controls the collision point in the Tevatron during the Fermilab colliding beams HEP program with 0.689 mm resolution
  • Keywords
    beam handling techniques; cavity resonators; proton accelerators; synchrotrons; Fermilab Main Ring; RF buckets; RF synchronous transfer; Tevatron accelerator; colliding beams HEP program; collision point; design philosophy; hardware implementation; phase coordinate placement; Acceleration; Colliding beam accelerators; Control systems; Forging; Frequency modulation; Frequency synchronization; Oscillators; Particle beam injection; Particle beams; Radio frequency;