DocumentCode
197444
Title
Convertidor CC-CC con puentes duales activos trifásicos: Comparación transformador YY y ΔΔ
Author
Nunez, Ruben O. ; Oggier, German G. ; Botteron, Fernando ; Garcia, Guillermo O.
Author_Institution
Grupo de Electrónica Aplicada (GEA) - CONICET, Facultad de Ingeniería, UNRC, Ruta Nacional #36, km #601, X5804BYA, Río Cuarto, Córdoba, Argentina
fYear
2014
fDate
11-13 June 2014
Firstpage
332
Lastpage
337
Abstract
This paper evaluates and compares the performance of a DC-DC converter with dual active three phase bridges using a three-phase high frequency transformer with star-star connection (DAB3YY) and delta-delta connection (DAB3ΔΔ). The objective of this comparison is to evaluate the stress of the power semiconductors based on the RMS values and the sum of the current as well as the transformer apparent power. From the analysis we conclude that the leakage inductance of the transformer DAB3ΔΔ should be three times greater than that of DAB3YY to transfer the same power. Furthermore, it is concluded that the stress on semiconductors and apparent power are the same on both connections, demonstrating the feasibility of using the DAB3ΔΔ.
fLanguage
English
Publisher
ieee
Conference_Titel
Biennial Congress of Argentina (ARGENCON), 2014 IEEE
Conference_Location
Bariloche, Argentina
Print_ISBN
978-1-4799-4270-1
Type
conf
DOI
10.1109/ARGENCON.2014.6868515
Filename
6868515
Link To Document