DocumentCode :
1975717
Title :
Large aperture quadrupoles for RHIC interaction regions
Author :
Gupta, R. ; Anerella, M. ; Ganetis, G. ; Garber, M. ; Ghosh, A. ; Greene, A. ; Jain, A. ; Kahn, S. ; Kelly, E. ; Killian, E. ; Morgan, G. ; Morgillo, A. ; Muratore, J. ; Prodell, A. ; Rehak, M. ; Sampson, W. ; Shutt, R. ; Thompson, P. ; Wanderer, P. ; Wil
Author_Institution :
Brookhaven Nat. Lab., Upton, NY, USA
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
2745
Abstract :
The ultimate luminosity performance of the Relativistic Heavy Ion Collider (RHIC) depends on the field quality in the large aperture (130 mm) superconducting quadrupoles in the interaction regions. In this paper we discuss the design features that are incorporated to obtain a good field quality. Coil midplane gap and pole shims may be adjusted to remove certain field harmonics due to systematic errors in construction. Iron tuning shims will be inserted at eight strategic locations in the assembled magnets to correct the measured values of harmonics in each magnet. The performance of two prototype magnets and upgrades under consideration will be discussed
Keywords :
beam handling equipment; beam handling techniques; ion accelerators; storage rings; synchrotrons; tuning; 130 mm; Fe tuning shims; RHIC interaction regions; Relativistic Heavy Ion Collider; coil midplane gap; field harmonics; field quality; interaction regions; large aperture quadrupoles; large aperture superconducting quadrupoles; prototype magnets; ultimate luminosity performance; Apertures; Assembly; Iron; Laboratories; Magnetic field measurement; Structural beams; Superconducting cables; Superconducting coils; Superconducting filaments and wires; Superconducting magnets;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
Type :
conf
DOI :
10.1109/PAC.1993.309447
Filename :
309447
Link To Document :
بازگشت