DocumentCode
1976328
Title
Sextupole magnets for the Fermilab Main Injector
Author
Harding, D.J. ; Chester, N. ; Baiod, R.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
2826
Abstract
A sextupole magnet has been designed to satisfy the dynamical, geometrical, and electrical requirements of the Fermilab Main Injector. The steel length is 0.457 m. The top and bottom pole tips are 26.4 mm from the center line. the side pole tips are 48.0 mm from the center line. The design integrated strength is 55 T-m/m2 at 294 A
Keywords
beam handling equipment; beam handling techniques; electromagnets; proton accelerators; synchrotrons; 0.457 m; 294 A; Fermilab Main Injector; bottom pole tip; center line; design integrated strength; dynamical requirements; electrical requirements; geometrical requirements; proton synchrotron; sextupole magnet; side pole tips; steel length; top pole tip; Circuit testing; Coils; Conducting materials; Cooling; Costs; Inductance; Laboratories; Magnets; Power supplies; Steel;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309474
Filename
309474