DocumentCode :
1976385
Title :
Magnetic measurement of quadrupole and sextupole magnets for the MIT-Bates South Hall Ring (SHR)
Author :
Tieger, D.R. ; Zumbro, J.D. ; Sapp, W.W.
Author_Institution :
Bates Linear Accel. Center, Middleton, MA, USA
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
2832
Abstract :
Final results of magnetic measurements of 128 quadrupoles and 32 sextupoles are presented. There are many places in the SHR complex where these magnets will be operated from a common power supply. For the quadrupole magnets there are 4 octets, 4 triplets and 18 doublets; these magnets have been matched to ±0.1% in excitation response for the operating range corresponding to 0.3-1.0 GeV. For the sextupoles there are four octets where the (pairwise) matching has generally been made to the ±0.3% level. Parameterization of the data as well as fits are described and examples of the magnet groupings are shown
Keywords :
beam handling equipment; magnetic field measurement; storage rings; MIT-Bates South Hall Ring; doublets; excitation response; magnet groupings; magnetic measurements; octets; quadrupole magnets; sextupole magnets; triplets; Coils; Data mining; Geometry; Harmonic analysis; Linear accelerators; Magnetic analysis; Magnetic variables measurement; Magnets; Power supplies; Q measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
Type :
conf
DOI :
10.1109/PAC.1993.309476
Filename :
309476
Link To Document :
بازگشت