• DocumentCode
    1978176
  • Title

    Notice of Retraction
    Fault analysis of Un-transposed three-phase based on Fortescue transformation matrix

  • Author

    Bo Liu ; Qingchao Zhang

  • Author_Institution
    Sch. of Electr. Eng. & Autom., Tianjin Univ., Tianjin, China
  • fYear
    2011
  • fDate
    16-18 Sept. 2011
  • Firstpage
    5920
  • Lastpage
    5923
  • Abstract
    Notice of Retraction

    After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.

    We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.

    The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.

    Fortescue´s transformation is a well-known matrix which can be used for fault analysis of perfectly transposed three-phase lines, but for un-transposed asymmetrical transmission lines, the parameter matrices of line such as impedance matrix and admittance matrix are no longer circulant matrices, It means that the Fortescue transformation matrix can not digitalization of the parameters. Nevertheless, the transformation matrix can still play an important role in contacting with the exact modal transformation. This paper introduces a correction method on the base of Fortescue´s transformation matrix, and the corrected transformation matrix is applied in the mode component method. The error of result shows that the corrected transformation matrix is feasible for the fault analysis of weak geometry unbalances transmission line and the method can make the calculation process simplify.
  • Keywords
    matrix algebra; power transmission faults; transmission network calculations; Fortescue transformation matrix; correction method; fault analysis; three phase lines; untransposed three phase; Eigenvalues and eigenfunctions; Load modeling; Mathematical model; Power transmission lines; Symmetric matrices; Transmission line matrix methods; Fortescue matrix; asymmetrical; fault analysis; mode component method; un-transposed transmission line;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Control Engineering (ICECE), 2011 International Conference on
  • Conference_Location
    Yichang
  • Print_ISBN
    978-1-4244-8162-0
  • Type

    conf

  • DOI
    10.1109/ICECENG.2011.6057294
  • Filename