DocumentCode
1978176
Title
Notice of Retraction
Fault analysis of Un-transposed three-phase based on Fortescue transformation matrix
Author
Bo Liu ; Qingchao Zhang
Author_Institution
Sch. of Electr. Eng. & Autom., Tianjin Univ., Tianjin, China
fYear
2011
fDate
16-18 Sept. 2011
Firstpage
5920
Lastpage
5923
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
Fortescue´s transformation is a well-known matrix which can be used for fault analysis of perfectly transposed three-phase lines, but for un-transposed asymmetrical transmission lines, the parameter matrices of line such as impedance matrix and admittance matrix are no longer circulant matrices, It means that the Fortescue transformation matrix can not digitalization of the parameters. Nevertheless, the transformation matrix can still play an important role in contacting with the exact modal transformation. This paper introduces a correction method on the base of Fortescue´s transformation matrix, and the corrected transformation matrix is applied in the mode component method. The error of result shows that the corrected transformation matrix is feasible for the fault analysis of weak geometry unbalances transmission line and the method can make the calculation process simplify.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
Fortescue´s transformation is a well-known matrix which can be used for fault analysis of perfectly transposed three-phase lines, but for un-transposed asymmetrical transmission lines, the parameter matrices of line such as impedance matrix and admittance matrix are no longer circulant matrices, It means that the Fortescue transformation matrix can not digitalization of the parameters. Nevertheless, the transformation matrix can still play an important role in contacting with the exact modal transformation. This paper introduces a correction method on the base of Fortescue´s transformation matrix, and the corrected transformation matrix is applied in the mode component method. The error of result shows that the corrected transformation matrix is feasible for the fault analysis of weak geometry unbalances transmission line and the method can make the calculation process simplify.
Keywords
matrix algebra; power transmission faults; transmission network calculations; Fortescue transformation matrix; correction method; fault analysis; three phase lines; untransposed three phase; Eigenvalues and eigenfunctions; Load modeling; Mathematical model; Power transmission lines; Symmetric matrices; Transmission line matrix methods; Fortescue matrix; asymmetrical; fault analysis; mode component method; un-transposed transmission line;