A comparison between impedance measured by a commercial analyzer and your value adjusted by a theoretical model in body composition evaluation
Author :
Neves, C.E.B. ; Souza, M.N.
Author_Institution :
COPPE, Univ. Fed. do Rio de Janeiro, Brazil
Volume :
4
fYear :
2001
fDate :
2001
Firstpage :
3388
Abstract :
The use of an electrical current for the evaluation of several physiological variables in the human body is not a recent technique but continues to awaken great interest in the research community. One of the greatest applications for such a technique is the study of body composition through bioimpedance, where generally a equipment with a tetrapolar array set of electrodes is used to realize the bioimpedance measurement. The aim of the present work is to show that the bioimpedance measured is normally sub-estimated and to develop a correction factor for such values. The comparison between the original bioimpedance values, obtained by commercial equipment, and their corrected values, in body composition evaluation, will be shown. Body composition tests were conducted on 10 male subjects. Besides the bioimpedance analysis, anthropometric measures consisting of height, weight and skinfold-thickness were also obtained from the subjects to allow an estimation of the body composition by anthropometric equations established in the literature. The comparison results point to a better correlation (Pearson coefficient, r = 0.9735) between the anthropometric estimated fat-free mass (FFM) and the estimated value by the corrected bioimpedance adjusted, when compared with the original ones Pearson coefficient, r = 0.9487.
Keywords :
bioelectric phenomena; biomedical electrodes; biomedical measurement; electric impedance measurement; measurement errors; Pearson coefficient; anthropometric estimated fat-free mass; anthropometric measures; bioimpedance; body composition evaluation; commercial analyzer; correction factor; electrical current; electrode tetrapolar array set; estimated value; height; human body; impedance; physiological variables; skinfold-thickness; weight; Bioelectric phenomena; Bioimpedance; Biomedical engineering; Biomedical measurements; Current measurement; Electrodes; Impedance measurement; Physiology; Preamplifiers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
ISSN :
1094-687X
Print_ISBN :
0-7803-7211-5
Type :
conf
DOI :
10.1109/IEMBS.2001.1019556
Filename :
1019556
Link To Document :
بازگشت