• DocumentCode
    1981961
  • Title

    Parameters that influence power quality on industrial frequency AC traction systems

  • Author

    Morrison, R.E.

  • Author_Institution
    Centre for Electr. Power Eng., Monash Univ., Clayton, Vic., Australia
  • Volume
    1
  • fYear
    2001
  • fDate
    15-19 July 2001
  • Firstpage
    204
  • Abstract
    It is proposed that power quality In AC railway systems should consider low voltage, high voltage form factor and resonant overvoltage rather than the parameters normally considered for public utilities. Each of the 3 system aspects has a conventional means of compensation and a solution using power electronic systems. The paper describes the potential power quality problem areas on AC traction systems and possible means of compensation. The conclusion Is drawn that disturbance levels on AC traction systems are likely to remain higher than disturbance levels within public electricity supplies to achieve lower capital cost for railway networks.
  • Keywords
    compensation; harmonic distortion; power supply quality; power system harmonics; railways; traction; AC railway power systems; capital cost; compensation; form factor; industrial frequency AC traction systems; power electronic systems; power quality; public electricity supplies; resonant overvoltage; Australia; Control systems; Frequency; Low voltage; Power electronics; Power quality; Rail transportation; Resonance; Vehicles; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Society Summer Meeting, 2001
  • Conference_Location
    Vancouver, BC, Canada
  • Print_ISBN
    0-7803-7173-9
  • Type

    conf

  • DOI
    10.1109/PESS.2001.970013
  • Filename
    970013