• DocumentCode
    1987528
  • Title

    Starting study of DC inverter compressor

  • Author

    Yu, Shiqiu

  • Author_Institution
    Electron. & Inf. Coll., Yangtze Univ., Jingzhou, China
  • fYear
    2011
  • fDate
    16-18 Sept. 2011
  • Firstpage
    835
  • Lastpage
    837
  • Abstract
    With DC inverter compressors starting characteristics, the three-step starting method was used. The role of 3-steps and the transition in them was researched, the control method of preposition phase and forced synchronous phase is proposed. Focusing on the step time control law of forced synchronous phase in variable load startup, the step time control method is obtained and the research results is confirmed by prototype test.
  • Keywords
    compressors; invertors; phase control; position control; DC inverter compressor; forced synchronous phase; forced synchronous phase control method; preposition phase control method; step time control law; three-step starting method; variable load startup; Brushless DC motors; Commutation; Educational institutions; Focusing; Integrated circuits; Inverters; World Wide Web; 3-step; BLDC; DC inverter compressor; startup;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Control Engineering (ICECE), 2011 International Conference on
  • Conference_Location
    Yichang
  • Print_ISBN
    978-1-4244-8162-0
  • Type

    conf

  • DOI
    10.1109/ICECENG.2011.6057720
  • Filename
    6057720