DocumentCode :
1988563
Title :
Assessment of direct VRM topologies
Author :
Ribes-Mallada, U. ; Leyva, R. ; Garcés, P.
Author_Institution :
Dept. Eng. Electron. Electr. i Autom., Univ. Rovira i Virgili, Tarragona, Spain
fYear :
2011
fDate :
15-18 May 2011
Firstpage :
765
Lastpage :
768
Abstract :
The paper describes an efficiency comparison between two VRM topologies, concretely the synchronous buck and the synchronous cascade-buck converters. The comparison is carried out among optimal designs. The comparison is made among designs that have the same size of the output filter or the same ripple values. The paper shows that synchronous cascade-buck converter is more efficient, although the current must go through two switches.
Keywords :
power convertors; voltage regulators; direct VRM topologies; output filter; ripple values; synchronous cascade-buck converters; voltage regulator modules; Capacitors; Inductance; Inductors; MOSFETs; Microprocessors; Switching frequency; Topology;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Circuits and Systems (ISCAS), 2011 IEEE International Symposium on
Conference_Location :
Rio de Janeiro
ISSN :
0271-4302
Print_ISBN :
978-1-4244-9473-6
Electronic_ISBN :
0271-4302
Type :
conf
DOI :
10.1109/ISCAS.2011.5937678
Filename :
5937678
Link To Document :
بازگشت