Abstract
In this paper the influences of various pulse durations and reference cell types on CIGS thin-film PV module performance measurements with a long-pulse solar simulator are presented. Pulse duration between 50ms to 1050ms is chosen by long-pulse solar simulator in the study. The differences of module performance caused by using monolysilicon and polysilicon reference cells with/without EVA, respectively, to monitor simulator irradiance are compared. Furthermore, measurements uncertainty of testing laboratory is discussed in study for estimating the capacity of PV module indoor testing.
Keywords
copper compounds; elemental semiconductors; gallium compounds; indium compounds; measurement uncertainty; semiconductor thin films; silicon; solar cells; ternary semiconductors; CIGS thin-film PV module performance measurements; Cu(GaIn)Se2; EVA; PV module indoor testing; Si; long-pulse solar simulator; measurements uncertainty; monolysilicon reference cells; polysilicon reference cells; pulse durations; reference cells; simulator irradiance; testing laboratory; time 50 ms to 1050 ms; Current measurement; IEC standards; Measurement uncertainty; Pulse measurements; Testing; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering and Technology (S-CET), 2012 Spring Congress on
Conference_Location
Xian
Print_ISBN
978-1-4577-1965-3
Type
conf
DOI
10.1109/SCET.2012.6341935
Filename
6341935
Link To Document