• DocumentCode
    1989695
  • Title

    Two dimensional phase sensitive surface plasmon resonance biosensor array using microfluidic flow circuit platform

  • Author

    Wong, Chi Lok ; Ho, Ho Pui ; Lei, Kin Fong ; Li, Wen Jung ; Chan, Kwok Sum ; Law, Wing Cheung ; Wu, Shu Yuen ; Kong, Siu Kai ; Lin, Chinlon

  • Author_Institution
    Department of Electronic Engineering, The Chinese University of Hong Kong
  • fYear
    2005
  • fDate
    19-21 Dec. 2005
  • Firstpage
    709
  • Lastpage
    712
  • Abstract
    The integration between 2D SPR differential phase imaging sensor and microfluidic flow circuit is presented. It provides the advantages of high throughput, high sensitivity and label free detection to meet the present needs in biomechnical market. The differential phase scheme between p- and s- polarization enable elimination of all common-path phase noise while keeping the phase change caused by SPR effect. System sensitivity of the detection sensitivity of our setup is 0.44μg /ml is obtained for salt / water mixture sensing. BSA antigen and antibody binding reaction detection is further demonstrated. The system shows the capability of simultaneous detection for both specific and non-specific binding reactions in a micro-chamber array.
  • Keywords
    Biosensors; Image sensors; Microfluidics; Phase noise; Phased arrays; Plasmons; Polarization; RLC circuits; Resonance; Throughput;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices and Solid-State Circuits, 2005 IEEE Conference on
  • Print_ISBN
    0-7803-9339-2
  • Type

    conf

  • DOI
    10.1109/EDSSC.2005.1635374
  • Filename
    1635374