• DocumentCode
    1992765
  • Title

    An in-vivo evaluation of the effects of anesthesia carrier gases on ultrasound contrast agent circulation

  • Author

    Mullin, Lee ; Gessner, Ryan ; Kwan, James ; Borden, Mark A. ; Dayton, Paul A.

  • Author_Institution
    Joint Dept. of Biomed. Eng., Univ. of North Carolina, Chapel Hill, NC, USA
  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    1290
  • Lastpage
    1293
  • Abstract
    Both clinical and preclinical ultrasound imaging studies use microbubble contrast agents. Short in-vivo lifetimes limit the diagnostic and therapeutic capabilities of these contrast agents, and currently there is research interest in how to lengthen their circulation times. Differences have been observed in contrast agent circulation times during preclinical studies depending on the type of inhaled anesthesia carrier gas. This paper presents the observations from a controlled experiment that evaluated differences in circulation times for lipid shelled perfluorocarbon-filled contrast agents circulating in rodents as a function of inhaled anesthesia carrier gas. Both pure oxygen and medical air are considered and we discuss the persistence of the contrast agents as determined by ultrasound video intensity. The results show a significantly longer in-vivo contrast agent circulation for animals breathing medical air as compared to breathing pure oxygen. Simulations show enhanced contrast persistence may be explained by classical diffusion and that nitrogen plays a critical role by contributing to the volume and diluting the other gas species in the microbubble gas core.
  • Keywords
    biodiffusion; biomedical ultrasonics; bubbles; drugs; haemodynamics; lipid bilayers; microfluidics; pneumodynamics; anesthesia carrier gases effects; animals breathing; classical diffusion; gas dilution; inhalation; lipid shelled perfluorocarbon-filled contrast agents; medical air; microbubble; nitrogen; pure oxygen; ultrasound imaging; Anesthesia; Animals; Biomedical imaging; Gases; Lipidomics; Medical diagnostic imaging; Medical simulation; Nitrogen; Rodents; Ultrasonic imaging; anesthesia; carrier gas; circulation time; lifetime; microbubble; persistence;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441486
  • Filename
    5441486