  • Abstract
    An enhanced approach in which the windowed chirp transmission is inverse filtered with the impulse response of an ultrasonic transducer is investigated to improve axial resolution and to reduce the side lobe level in high frequency coded excitation imaging. This method reduces side-lobe level more than the resolution enhancement compression (REC) method without using a mismatched filter. The proposed method modifies the number of samples of transmission signal to maintain the accuracy of convolution operation while performing inverse filtering. In this way, side-lobe level is minimized compared to the REC method without a loss of axial resolution. Both simulation and experimental measurements were carried out to validate the enhanced method. FieldII simulation was performed for a 34 MHz focused single element transducer. For the experimental measurement, a focused LiNbO3 single element transducer at 34 MHz center frequency with 74% bandwidth was used. The two way impulse response of transducer was acquired by pulse-echo measurements. The frequency of the Hanning windowed chirp was from 20 MHz to 60 MHz. Images of a wire target and rabbit eyeball were acquired for the image evaluation. The simulation results showed that the axial resolution at -6dB was enhanced from 53¿m to 48¿m at the focal point of transducer whereas experimental results showed that the axial resolution at -6dB was enhanced from 52¿m to 46¿m and side-lobe level of proposed method was decreased by 4dB compared with the REC method.
  • Keywords
    acoustic convolution; chirp modulation; ultrasonic imaging; ultrasonic transducers; Hanning windowed chirp; REC method; axial resolution loss; convolution operation; focused single element transducer; high frequency coded excitation imaging; impulse response; inverse filtering; pulse echo measurement; rabbit eyeball; resolution enhancement compression; side lobe level reduction; ultrasonic transducer response compensation; windowed chirp transmission; wire target; Chirp; Filters; Focusing; Frequency; High-resolution imaging; Image resolution; Pulse measurements; Signal resolution; Ultrasonic imaging; Ultrasonic transducers; Hanning window; high frequency coded excitation; inverse filter; resolution enhancement compression;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441579
  • Filename
    5441579