• DocumentCode
    1995663
  • Title

    Detection of partially fallen-out magnetic slot wedges in inverter fed AC machines under various load conditions

  • Author

    Stojicic, Goran ; Vasak, Mario ; Peric, Nedjeljko ; Joksimovic, Gojko ; Wolbank, Thomas M.

  • Author_Institution
    Dept. of Energy Syst. & Electr. Drives, Vienna Univ. of Technol., Vienna, Austria
  • fYear
    2012
  • fDate
    15-20 Sept. 2012
  • Firstpage
    4015
  • Lastpage
    4020
  • Abstract
    Electrical machines in the high voltage class are usually designed with open stator slots. This wide open slots cause an increase of higher order harmonics, vibrations, noise and temperature, thus the machines efficiency is decreased. To counteract this disadvantage magnetic slot wedges are applied. Due to the impact of high magnetic and mechanical forces these wedges can fall out and may cause further serious damages. Up to now reliable detection methods for single missing slot wedges are coupled with a disassembling of parts of the machine. In this paper an method is investigated which provides the possibility of detection, based on the measurement of electrical terminal quantities only.
  • Keywords
    AC machines; invertors; stators; vibrations; electrical machines; electrical terminal quantity measurement; high magnetic forces; higher order harmonics; inverter fed AC machines; mechanical forces; open stator slots; partially fallen-out magnetic slot wedge detection method; single missing slot wedges; vibrations; Current measurement; Inductance; Inverters; Rotors; Stator windings; Transient analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2012 IEEE
  • Conference_Location
    Raleigh, NC
  • Print_ISBN
    978-1-4673-0802-1
  • Electronic_ISBN
    978-1-4673-0801-4
  • Type

    conf

  • DOI
    10.1109/ECCE.2012.6342278
  • Filename
    6342278