Title
Detection of partially fallen-out magnetic slot wedges in inverter fed AC machines under various load conditions
Author
Stojicic, Goran ; Vasak, Mario ; Peric, Nedjeljko ; Joksimovic, Gojko ; Wolbank, Thomas M.
Author_Institution
Dept. of Energy Syst. & Electr. Drives, Vienna Univ. of Technol., Vienna, Austria
fYear
2012
fDate
15-20 Sept. 2012
Firstpage
4015
Lastpage
4020
Abstract
Electrical machines in the high voltage class are usually designed with open stator slots. This wide open slots cause an increase of higher order harmonics, vibrations, noise and temperature, thus the machines efficiency is decreased. To counteract this disadvantage magnetic slot wedges are applied. Due to the impact of high magnetic and mechanical forces these wedges can fall out and may cause further serious damages. Up to now reliable detection methods for single missing slot wedges are coupled with a disassembling of parts of the machine. In this paper an method is investigated which provides the possibility of detection, based on the measurement of electrical terminal quantities only.
Keywords
AC machines; invertors; stators; vibrations; electrical machines; electrical terminal quantity measurement; high magnetic forces; higher order harmonics; inverter fed AC machines; mechanical forces; open stator slots; partially fallen-out magnetic slot wedge detection method; single missing slot wedges; vibrations; Current measurement; Inductance; Inverters; Rotors; Stator windings; Transient analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2012 IEEE
Conference_Location
Raleigh, NC
Print_ISBN
978-1-4673-0802-1
Electronic_ISBN
978-1-4673-0801-4
Type
conf
DOI
10.1109/ECCE.2012.6342278
Filename
6342278
Link To Document