Abstract :
Integration of a piezoelectric high frequency ultrasound (HFUS) array with a microfabricated application specific integrated circuit (ASIC) performing a range of functions has several advantages for ultrasound imaging. The number of signal cables between the array/electronics and the data acquisition / imaging system can be reduced, cutting costs and increasing functionality. Electrical impedance matching is also simplified and the same approach can reduce overall system dimensions for applications such as endoscopic ultrasound. The work reported in this paper demonstrates early ASIC operation with a piezocomposite HFUS array operating at approximately 30 MHz. The array was tested in three different modes. Clear signals were seen in catch-mode, with an external transducer as a source of ultrasound, and in pitch-mode with the external transducer as a receiver. Pitch-catch mode was also tested successfully, using sequential excitation on three array elements, and viable signals were detected. However, these were relatively small and affected by interference from mixed-signal sources in the ASIC. Nevertheless, the functionality and compatibility of the two main components of an integrated HFUS - ASIC device have been demonstrated and the means of further optimization are evident.
Keywords :
application specific integrated circuits; composite materials; impedance matching; piezoelectric transducers; ultrasonic imaging; ultrasonic transducer arrays; ASIC microfabrication; application specific integrated circuit; data acquisition; electrical impedance matching; endoscopic ultrasound; high frequency piezoelectric ultrasound array; imaging system; mixed-signal source; piezocomposite HFUS array; pitch-catch mode; signal cable; ultrasonic transducer; ultrasound imaging; Application specific integrated circuits; Cables; Cost function; Data acquisition; Frequency; Impedance matching; Sequential analysis; Testing; Ultrasonic imaging; Ultrasonic transducers; High frequency ultrasound; Integrated electronics; Ultrasound array;
Conference_Titel :
Ultrasonics Symposium (IUS), 2009 IEEE International
Conference_Location :
Rome
Print_ISBN :
978-1-4244-4389-5
Electronic_ISBN :
1948-5719
DOI :
10.1109/ULTSYM.2009.5441707