• DocumentCode
    1999491
  • Title

    Computational model of a phased array for image guided pediatric cardiac treatment

  • Author

    Mosse, R. ; Meyer, R.J., Jr. ; Ge, S. ; Smith, N.B.

  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    1306
  • Lastpage
    1309
  • Abstract
    A computational model of a planar, phased array transducer is developed to aid in the design of an high intensity, focused ultrasound transducer for the noninvasive treatment of congenital heart disease in newborns. The aim is to predict the size, shape and temperature of the high-intensity focal region, and acoustic artifacts surrounding the focal area, created by a transducer. Acoustic intensity fields are calculated and mapped by numerically integrating a form of the Rayleigh-Sommerfeld integral. The resulting temperature field is predicted by the Pennes bio-heat transfer equation by implementing a 3-dimensional finite difference method algorithm. Based on the metrics of an atrial septal defect and the metrics of isolated patent ductus arteriosis in consecutive human neonates, a first iteration of an array design has been performed. A random-sparse array configuration is used to reduce side-lobe and grating lobe effects. To avoid the scattering and reflecting effects of ribs, the transducer is configured to fit in the gaps between the ribs. The three arrays are phased act cooperatively as a single array. Each array contains 45 elements (3 × 15), with every third element active (45 total). The transducer was designed to have a center frequency of 1.2 MHz. A first iteration design was fabricated using PZT-8 piezoelectric ceramic. The exposimetry of the transducer was captured and compared to numerical models. The exposimetry results correspond well with the numerical models, warranting further development of the transducer design.
  • Keywords
    biomedical ultrasonics; biothermics; cardiology; diseases; finite difference methods; iterative methods; mathematical analysis; paediatrics; patient treatment; piezoceramics; 3-D finite difference method algorithm; PZT-8 piezoelectric ceramic; Pennes bio-heat transfer equation; Rayleigh-Sommerfeld integral; atrial septal defect; center frequency; computational model; congenital heart disease; high-intensity focal region; image guided pediatric cardiac treatment; isolated patent ductus arteriosis; noninvasive treatment; phased array; phased array transducer; random-sparse array configuration; ultrasound transducer; Acoustic transducers; Computational modeling; Numerical models; Pediatrics; Phased arrays; Piezoelectric transducers; Ribs; Temperature; Ultrasonic transducer arrays; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441771
  • Filename
    5441771