DocumentCode
2001525
Title
Reducing Non-Systematic Errors in Microstrip Measurements
Author
Jones, Keith E. ; Burcham, Terry E. ; Gleason, K.Reed
fYear
1988
fDate
12-15 Sept. 1988
Firstpage
919
Lastpage
923
Abstract
Accuracy of error-corrected network analyzer measurements is often limited by connection repeatability errors to the device under test. An improved coax to microstrip adapteris described which provides -46 dB repeatability to 26.5 GHz. Microstrip calibration standards were developed to permit adapter de-embedding. Data from a wafer-probed MESFET is compared to measurements of the same device bonded into a microstrip carrier.
Keywords
Calibration; Coaxial components; Connectors; Error analysis; Error correction; Insertion loss; MESFETs; Microstrip; Reflection; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 1988. 18th European
Conference_Location
Stockholm, Sweden
Type
conf
DOI
10.1109/EUMA.1988.333926
Filename
4132614