Title : 
Comparison of the coagulation effects on different coagulants in raw water treatment
         
        
            Author : 
Xia, Ping ; Ye, Hui ; Feng, Jun
         
        
            Author_Institution : 
Shanghai Municipal Water Resource Dev. & Utilization Nat. Eng. Center Co., Ltd., Shanghai, China
         
        
        
        
        
        
            Abstract : 
According to the quality of raw water in water plants, the pollution removal rates of three different coagulants dosage were compared. There search conclusion on coagulation effects of different coagulants. The results showed that the coagulation effect of PACS(B) was best, when the best of its injection was 30 mg/L, the removal turbidity rate was 94%, the removal color rate was 55%, the removal CODMn rate was 23% the removal manganese rate was 50%.
         
        
            Keywords : 
coagulation; manganese; turbidity; water pollution; water quality; water treatment; PACS; coagulant dosage; coagulation effect; pollution removal rate; raw water quality; raw water treatment; removal color rate; removal manganese rate; removal turbidity rate; water plant; Coagulation; Color; Companies; Monitoring; Picture archiving and communication systems; Water pollution; Water resources; PAC; PACS; coagulation; effect;
         
        
        
        
            Conference_Titel : 
Electrical and Control Engineering (ICECE), 2011 International Conference on
         
        
            Conference_Location : 
Yichang
         
        
            Print_ISBN : 
978-1-4244-8162-0
         
        
        
            DOI : 
10.1109/ICECENG.2011.6058440