• DocumentCode
    2004231
  • Title

    Simulation of acoustic fields from arbitrary transducer stacks using a FEM transducer model and nonlinear wave propagation

  • Author

    Frijlink, M.E. ; Torp, H.

  • Author_Institution
    Dept. of Circulation & Med. Imaging, Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    2340
  • Lastpage
    2343
  • Abstract
    Nonlinear acoustic field simulations can be useful for medical transducer design. An accurate estimation of the electro-mechanical transfer function of the acoustic stack, increases the accuracy of the predicted harmonic fields. In this study, we combined a 2D FEM model (using COMSOL) of the transducer stack, with a two-port model of the electrical transmit circuit, and the simulation program for nonlinear wave propagation Abersim. Example simulations showed the effect on the generated second harmonic field for simulated arrays with different elevation sizes, and different piezoelectric materials. Simulated arrays, (fc = 3 MHz, 64 elements, elevation and azimuth focus = 60 mm) with elevation sizes of 9, 11, and 13 mm, were excited with a square wave 3-half-cycle pulse (fc = 1.9 MHz, amplitude = 80 Vpp) through a transmit circuit consisting of a cable and inductive tuning. Nonlinear propagation through a tissue-like medium (attenuation = 0.3 dB/cm/MHz) resulted in maximum second harmonic pressures of 0.75, 0.93, and 1.1 MPa, for 9, 11 and 13 mm elevation, respectively. Simulations with different piezoelectric materials, showed that the single crystals PMN-33%PT and PZN-8%PT resulted in 7-8 dB higher second harmonic pressures than the PZT ceramics HD3202 and PZ21, for the same transmit conditions without tuning. Inductive tuning increased the efficiency for the PZT-ceramics by 6-8 dB, and for single crystals by 0-2 dB. These examples demonstrated how this comprehensive simulation tool could be used to optimize array design.
  • Keywords
    acoustic field; biomedical ultrasonics; finite element analysis; harmonic generation; nonlinear acoustics; piezoelectric transducers; ultrasonic propagation; ultrasonic transducer arrays; 2D FEM model; COMSOL; FEM transducer model; PZN-PT; PZT ceramics; arbitrary transducer stacks; array design; electrical transmit circuit; electro-mechanical transfer function; inductive tuning; medical transducer design; nonlinear acoustic field simulation; nonlinear wave propagation; piezoelectric material; second harmonic field generation; second harmonic pressure; single crystal PMN-PT; single crystals; square wave 3-half-cycle pulse; tissue-like medium; Acoustic transducers; Acoustic waves; Biomedical acoustics; Biomedical transducers; Circuit simulation; Crystals; Medical simulation; Nonlinear acoustics; Nonlinear wave propagation; Piezoelectric materials; Abersim; Finite Element Method; Nonlinear wave propagation; Transducer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441985
  • Filename
    5441985