Title :
Effects of unbalanced ionizers on magnetoresistive recording heads
Author :
Snyder, Harlan ; Wallash, Albert
Author_Institution :
Technical Consulting Associates, P.o. Box 2925 Saratoga, Ca. 95070
Abstract :
The purpose of this work is to study the effects of handling magnetoresistive (MR) recording heads near an unbalanced DC ionizer. A methodology for studying and measuring the charging and current transient behavior of an MR head as a function of ionizer imbalance is presented. SEM photographs of MR heads handled near an unbalanced ionizer show severe ESD damage of the MR sensor. A useful result is the measurement of the peak ESD current as a function of ionizer imbalance. It is concluded that DC ionizers must be properly maintained and carefully balanced in order to avoid harmful ESD currents in MR heads.
Keywords :
Conductors; Current measurement; Electromagnetic interference; Electromagnetic measurements; Electrostatic discharge; Electrostatic measurements; Magnetic heads; Magnetoresistance; Pollution measurement; Voltage;
Conference_Titel :
Electrical Overstress/Electrostatic Discharge Symposium,1997. Proceedings
Conference_Location :
Orlando, FL, USA
Print_ISBN :
1-878303-69-4
DOI :
10.1109/EOSESD.1997.634270