• DocumentCode
    2006145
  • Title

    Implementation of a Diagnostic Tool for Semi Permanent Electrical Contacts for a Direct Contact Force Measurement

  • Author

    Obame, H. Essone ; Carvou, E. ; Ben Jemaa, N. ; Cousin, Bernard ; Elabdi, R.

  • Author_Institution
    IPR, Univ. of Rennes, Rennes, France
  • fYear
    2013
  • fDate
    22-25 Sept. 2013
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    For long service functioning of semi permanent contacts, an optimal and stable contact force is needed. Mechanical stability of contacts leads to reliable electrical performance of the connector. However, a lowering of this contact force is often observed during operations. In a previous paper, information about the contact force was obtained from insertion force measurements together with the friction coefficient of the contact material. To avoid these parameters (insertion force and friction coefficient μ) that may change during mating cycle, an innovative diagnostic tool to directly measure the contact force of each spring of the connector has been investigated, in situ.
  • Keywords
    electric connectors; electrical contacts; mechanical stability; connector; contact material; direct contact force measurement; friction coefficient; innovative diagnostic tool; insertion force; insertion force measurements; long service functioning; mating cycle; mechanical stability; semipermanent electrical contacts; Connectors; Contacts; Force; Force measurement; Piezoresistance; Prototypes; Springs;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Holm Conference on Electrical Contacts (HOLM) , 2013 IEEE 59th
  • Conference_Location
    Newport, RI
  • ISSN
    1062-6808
  • Print_ISBN
    978-1-4799-1556-9
  • Type

    conf

  • DOI
    10.1109/HOLM.2013.6651415
  • Filename
    6651415