DocumentCode :
2008508
Title :
On-line intermittent connector anomaly detection
Author :
Ginart, Antonio E. ; Ali, Irfan N. ; Goldin, Jonathan W. ; Barlas, Irtaza ; Kalgren, Patrick ; Roemer, Michael J. ; Balaban, Edward
Author_Institution :
Impact Technol., LLC, Rochester, NY, USA
fYear :
2011
fDate :
12-15 Sept. 2011
Firstpage :
235
Lastpage :
239
Abstract :
This paper investigates a non-traditional use of differential current sensor and current sensor to detect intermittent disconnection problems in connectors. An intermittent disconnect, often resulting in an arc, creates an imbalance which is manifested in the current. The traveling wave generated due to the perturbation can be detected using current sensors. This paper shows the feasibility to detect disconnection based on this principle.
Keywords :
aircraft; arcs (electric); electric connectors; electric current measurement; electric sensing devices; space vehicles; arc; detect intermittent disconnection; differential current sensor; disconnection detection; on line intermittent connector anomaly detection; Actuators; Aircraft; Circuit faults; Connectors; Contacts; Current measurement; Power transmission lines; Connectors; PHM; arcing; disconnection; fault detection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
AUTOTESTCON, 2011 IEEE
Conference_Location :
Baltimore, MD
ISSN :
1088-7725
Print_ISBN :
978-1-4244-9362-3
Type :
conf
DOI :
10.1109/AUTEST.2011.6058777
Filename :
6058777
Link To Document :