Abstract
In this paper, the limits and consequences of an algorithm proposed in for the determination of the stator leakage reactance of synchronous machines are highlighted. This method requires the recording of the stator voltage/current characteristic of the machine unloaded and unexcited, in addition with the classical open-circuit characteristic. This approach has been implemented in our applications but instability problems appeared during the unloaded and unexcited test. In order to overcome this limitation, the use of a well-known alternative test (the slip test) in specific conditions is proposed here. We applied it to two types of synchronous machines (salient and non-salient pole synchronous machines) and have reached reliable results. Finally, in order to judge the efficiency of the method proposed in front of measurement errors, a sensitivity analysis was also conducted.
Keywords
machine testing; measurement errors; slip (asynchronous machines); stators; synchronous generators; machine testing; measurement error; nonsalient pole synchronous machine; open-circuit characteristics; reliability; salient synchronous machine; sensitivity analysis; slip test; stator leakage reactance determination; stator voltage-current characteristic; synchronous generator; Measurement errors; Reactive power; Rotors; Stators; Synchronous motors; Torque; Potier reactance; slip test; stator leakage reactance; synchronous machines;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Technology (ICIT), 2013 IEEE International Conference on
Conference_Location
Cape Town
Print_ISBN
978-1-4673-4567-5
Electronic_ISBN
978-1-4673-4568-2
Type
conf
DOI
10.1109/ICIT.2013.6505686
Filename
6505686
Link To Document