• DocumentCode
    2024173
  • Title

    Ultrasound elastography performance enhancement using wavelet denoising

  • Author

    Cui, Shaoguo ; Peng, Caibi ; Chen, Xiaolin ; Liu, Xiangyang ; Yu, Yong ; Wang, Qun

  • Author_Institution
    Comput. Center, Yunyang Med. Coll., Shiyan, China
  • fYear
    2010
  • fDate
    23-25 Nov. 2010
  • Firstpage
    1238
  • Lastpage
    1243
  • Abstract
    Ultrasound elastography is a kind of technique of obtaining the tissue relative stiffness information, which plays an important role in early tumor diagnosis. The increases in overlap between the data segments on the order of 90% or higher are essential to improve axial resolution in elastogaphy. However, correlated errors in displacement estimates increase dramatically with the increase in the overlap, and generate the so-called “worm” artefact. This results in a trade-off between the SNRe(CNRe) and the axial resolution. This paper presents a wavelet shrinkage denoising in strain estimates to reduce the worm artifact at a high overlap. The soft threshold function is selected and every adaptive threshold selection rule is tested to denoise the noisy strain estimates. The simulation results illustrate that the presented technique can efficiently denoise worm artefact and enhance the elastogram performance indices such as elastographic SNRe, CNRe while maintaining the high axial resolution. Elastogram obtained by wavelet denoising has the closest correspondence with ideal strain image(high correlation coefficient). In addition, the results also demonstrate that wavelet shrinkage denoising applied in strain estimates can obtain better image quality parameters than that applied in displacement estimates. The phantom experiments also show the similar elastogram performance improvement by using the proposed denoising technique.
  • Keywords
    biomedical ultrasonics; image resolution; signal denoising; tumours; wavelet transforms; adaptive threshold selection rule; axial resolution; correlation coefficient; data segment; early tumor diagnosis; elastogram performance indices; image quality; noisy strain estimate; phantom experiments; soft threshold function; strain image; tissue relative stiffness information; ultrasound elastography performance enhancement; wavelet shrinkage denoising; worm artefact; worm artifact; Filtering; Grippers; Lesions; Noise; Noise reduction; Strain; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Audio Language and Image Processing (ICALIP), 2010 International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4244-5856-1
  • Type

    conf

  • DOI
    10.1109/ICALIP.2010.5685130
  • Filename
    5685130