Title : 
Detection of plated through hole defects in printed circuit board with X-ray
         
        
            Author : 
Huang, Xingjia ; Zhu, Shengcong ; Huang, Xuanyu ; Su, Bing ; Ou, Changping ; Zhou, Weili
         
        
            Author_Institution : 
Advanced Engineering Division, CNSBG, Foxconn Technology Group, No.2, 2nd Donghuan Road, Longhua, Shenzhen, Guangdong, China
         
        
        
        
        
        
            Abstract : 
X-ray imaging provides direct visualization of sample´s internal structures and defects. Operation principles of two-dimensional X-ray and three-dimensional X-ray computer tomography are described. Two-dimensional X-ray provides real time imaging of samples, while three-dimensional X-ray computer tomography technology can reconstruct the three-dimensional image of the sample through processing a large number of single two-dimensional X-ray images. Moreover, the virtual cross-sections provided by three-dimensional X-ray computer tomography greatly benefit failure analysis engineers for failure localization. Two case studies are presented to demonstrate the application of X-ray inspection to detection of plated through hole defects in printed circuit board.
         
        
            Keywords : 
Computed tomography; Computers; Inspection; Soldering; Three-dimensional displays; X-ray imaging; 2D X-ray; 3D X-ray CT; PCB; PTH; X-ray inspection; annual ring defect; barrel crack; computer tomography;
         
        
        
        
            Conference_Titel : 
Electronic Packaging Technology (ICEPT), 2015 16th International Conference on
         
        
            Conference_Location : 
Changsha, China
         
        
        
            DOI : 
10.1109/ICEPT.2015.7236817