Title :
Detection methods for locating obstructions in blown optical fiber ducts
Author :
Cashdollar, Lucas ; Mazurowski, John ; Trageser, Andrew ; Keolian, Robert ; Poese, Matthew
Author_Institution :
Penn State Electro-Opt. Center, Freeport, PA, USA
Abstract :
Currently obstructions in blown optical fiber (BOF) tubing (microducts) are found using the ball bearing test (BB test) as described in test method 6H1 of MIL-STD-2042. A 4.5 millimeter (.17 inch) BB is launched down the entire length of the tubing (6 mm ID) with air pressure ranging from 50 to 100 psig. The BOF tubing is considered obstruction free if the BB can traverse the entire length of the tube. If the BB does not pass through the BOF tubing, there is an obstruction at an unknown location. Determining the position of this obstruction is time consuming, and if unsuccessful the entire BOF tube has to be scrapped. There would be a cost saving benefit if an accurate way of determining the location of the obstruction was found.
Keywords :
acoustic measurement; ball bearings; ducts; optical fibre testing; 6H1 test; BB test; BOF tubing; MIL-STD-2042; air pressure; ball bearing test; blown optical fiber ducts; blown optical fiber tubing; microducts; obstruction location; pressure 50 psi to 100 psi; size 4.5 mm; Acoustic measurements; Acoustics; Attenuation; Ducts; Electron tubes; Materials; Military standards;
Conference_Titel :
Avionics, Fiber- Optics and Photonics Technology Conference (AVFOP), 2012 IEEE
Conference_Location :
Cocoa Beach, FL
Print_ISBN :
978-1-4577-0757-5
DOI :
10.1109/AVFOP.2012.6344078