Title : 
An improved method for detecting and identifying gross errors simultaneously
         
        
            Author : 
Dong, Zhijun ; Wang, Shiguang
         
        
            Author_Institution : 
Dept. of Chem. Eng., Dalian Univ. of Technol., China
         
        
        
        
        
        
            Abstract : 
A linear combination technology is applied to identify gross errors (bias and leaks) and estimate their magnitude in a linear steady state process. A linear combination scheme is used firstly to isolate the candidate subset of gross errors and then simultaneous identification/estimation of gross errors is accomplished. Comparative studies of performance is performed on a recycle network and a steam system simulation results show that the proposed approach has higher performance for identifying gross errors as well as to estimate their magnitude.
         
        
            Keywords : 
chemical technology; error statistics; identification; bias; data reconciliation; gross errors; leaks; linear combination technology; linear steady state process; recycle network; steam system simulation; Automation; Chemical engineering; Chemical technology; Isolation technology; Recycling; State estimation; Steady-state;
         
        
        
        
            Conference_Titel : 
Intelligent Control and Automation, 2002. Proceedings of the 4th World Congress on
         
        
            Print_ISBN : 
0-7803-7268-9
         
        
        
            DOI : 
10.1109/WCICA.2002.1022216