Title :
Efficient Determination of the Uncertainty for the Optimization of SPECT System Design: A Subsampled Fisher Information Matrix
Author :
Fuin, Niccolo ; Pedemonte, Stefano ; Arridge, Simon ; Ourselin, Sebastien ; Hutton, Brian F.
Author_Institution :
Inst. of Nucl. Med., Univ. Coll. London Hosp., London, UK
Abstract :
System designs in single photon emission tomography (SPECT) can be evaluated based on the fundamental trade-off between bias and variance that can be achieved in the reconstruction of emission tomograms. This trade off can be derived analytically using the Cramer-Rao type bounds, which imply the calculation and the inversion of the Fisher information matrix (FIM). The inverse of the FIM expresses the uncertainty associated to the tomogram, enabling the comparison of system designs. However, computing, storing and inverting the FIM is not practical with 3-D imaging systems. In order to tackle the problem of the computational load in calculating the inverse of the FIM, a method based on the calculation of the local impulse response and the variance, in a single point, from a single row of the FIM, has been previously proposed for system design. However this approximation (circulant approximation) does not capture the global interdependence between the variables in shift-variant systems such as SPECT, and cannot account e.g., for data truncation or missing data. Our new formulation relies on subsampling the FIM. The FIM is calculated over a subset of voxels arranged in a grid that covers the whole volume. Every element of the FIM at the grid points is calculated exactly, accounting for the acquisition geometry and for the object. This new formulation reduces the computational complexity in estimating the uncertainty, but nevertheless accounts for the global interdependence between the variables, enabling the exploration of design spaces hindered by the circulant approximation. The graphics processing unit accelerated implementation of the algorithm reduces further the computation times, making the algorithm a good candidate for real-time optimization of adaptive imaging systems. This paper describes the subsampled FIM formulation and implementation details. The advantages and limitations of the new approximation are explored, in comparison with the circulant approxima- ion, in the context of design optimization of a parallel-hole collimator SPECT system and of an adaptive imaging system (similar to the commercially available D-SPECT).
Keywords :
adaptive systems; collimators; graphics processing units; image reconstruction; image sampling; medical image processing; optimisation; single photon emission computed tomography; 3D imaging systems; Cramer-Rao type bounds; FIM computing; FIM inverting; FIM storing; SPECT system design; acquisition geometry; adaptive imaging systems; data truncation; emission tomogram reconstruction; graphics processing unit; local impulse response; parallel-hole collimator SPECT system; real-time optimization; shift-variant systems; single photon emission tomography; subsampled Fisher information matrix; Approximation methods; Cameras; Image reconstruction; Optimization; Single photon emission computed tomography; Uncertainty; D-SPECT; Fisher information; emission tomography; reconstruction image quality; system design;
Journal_Title :
Medical Imaging, IEEE Transactions on
DOI :
10.1109/TMI.2013.2292805