DocumentCode
2033965
Title
Number of lightning to earth in Italy
Author
Bernardi, Marina ; Tommasini, Riccardo
Author_Institution
CESI s.p.a., Milan, Italy
fYear
2012
fDate
2-7 Sept. 2012
Firstpage
1
Lastpage
5
Abstract
After twelve years of operation, the lightning location system installed in Italy by CESI s.p.a. (named CESI SIRF®) collected over fifteen millions of lightning data. The present paper shows the methodology applied to these data, in order to evaluate the ground flash density (Ng) in Italy, under the supervision of the Italian Standards (CEI). A critical step was to take into account all data losses due to sensor temporary failures and to the intrinsic network efficiency. The choice of the calculation step for the geographic grid kept into account both influence on the Ng representation and Standards needs. The resulting Ng map will appear in the new CEI publication on ground flash density.
Keywords
earthing; lightning protection; CEI publication; Italian standards; data losses; earth; geographic grid; ground flash density evaluation; intrinsic network efficiency; lightning data; lightning location system; temporary failures; Approximation methods; Lightning; ground flash density; lightning; lightning location system;
fLanguage
English
Publisher
ieee
Conference_Titel
Lightning Protection (ICLP), 2012 International Conference on
Conference_Location
Vienna
Print_ISBN
978-1-4673-1898-3
Electronic_ISBN
978-1-4673-1896-9
Type
conf
DOI
10.1109/ICLP.2012.6344368
Filename
6344368
Link To Document