• DocumentCode
    2034698
  • Title

    Optical emission characteristics of a triple junction

  • Author

    Fréchette, Michel F. ; Larocque, René Y.

  • Author_Institution
    Inst. de Recherche, Hydro-Quebec, Varennes, Que., Canada
  • fYear
    2004
  • fDate
    17-20 Oct. 2004
  • Firstpage
    572
  • Lastpage
    575
  • Abstract
    Only when an AC voltage was applied under compressed air that discharging initiated at the triple junction. Under negative corona conditions in air at threshold, the DC discharge initiated at the apex of the point electrode. The infrequent burst did not make contact with the epoxy plane as the discharge grew away in the opposite direction. DC discharge in vacuum came to life preferably on the insulating plane facing the electrode.
  • Keywords
    air insulation; corona; electrodes; epoxy insulation; vacuum breakdown; vacuum insulation; DC vacuum discharge; applied AC voltage; compressed air; discharge initiation; epoxy plane; insulating medium; metallic electrode; negative corona conditions; plane/point/plane electrode configuration; point electrode apex discharge; solid insulator; triple junction optical emission characteristics; Bars; Cameras; Electrodes; Fault location; Geometrical optics; Insulation; Optical pulses; Solids; Stimulated emission; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2004. CEIDP '04. 2004 Annual Report Conference on
  • Print_ISBN
    0-7803-8584-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2004.1364314
  • Filename
    1364314