• DocumentCode
    2034741
  • Title

    Operational analysis of electric field mills as lightning warning systems in Colombia

  • Author

    Aranguren, D. ; Inampués, J. ; Torres, H. ; López, J. ; Pérez, Ernesto

  • Author_Institution
    Res. Program of Acquisition & Anal. of Signals, Nat. Univ. of Colombia, Bogota, Colombia
  • fYear
    2012
  • fDate
    2-7 Sept. 2012
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Electrostatic field measurements obtained in Bogotá-Colombia during thunderstorm episodes in November (common raining season due to the intertropical confluence zone over central Colombia) were used to study the performance of an isolated electric field sensor and analyze its most important operational characteristics. Distances from each flash to the studied sensor were obtained by using the Colombian lightning location system. The ΔE vs distance relation allowed defining a charge model which can be used as a reference for calibrating other electrostatic field sensors to be used as lightning warning systems.
  • Keywords
    electric field measurement; electric fields; electric sensing devices; lightning; lightning protection; thunderstorms; Colombian lightning location system; charge model; distance relation; electric field mill; electrostatic field measurement; electrostatic field sensor; isolated electric field sensor; lightning warning system; operational characteristics; thunderstorm; Brushless motors; Sensitivity; electric field mill; lightning warning system; operational analysis; thunderstorms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Lightning Protection (ICLP), 2012 International Conference on
  • Conference_Location
    Vienna
  • Print_ISBN
    978-1-4673-1898-3
  • Electronic_ISBN
    978-1-4673-1896-9
  • Type

    conf

  • DOI
    10.1109/ICLP.2012.6344398
  • Filename
    6344398