Title :
Advanced non-destructive fault isolation using computed tomography in flip-chip devices
Author :
Syahirah, Z. ; Gopmath, R. ; Tay, M.Y.
Author_Institution :
Device Anal. Lab., Adv. Micro Devices (Singapore) Pte Ltd., Singapore, Singapore
Abstract :
As package integration has reached a saturation point in device miniaturization, fault isolation of flip-chip packaging defects using real-time X-ray, even when using high-magnification viewing, is facing more challenges due to the increase in package complexity and shrinking package dimensions. Computed tomography (CT) X-ray is a solution to overcome this problem. This paper compares defect detection between 2D and 3D X-ray images using the CT X-ray platform. We present specific case study discussions of various defects that were challenging for 2D X-ray but effectively isolated by 3D X-ray.
Keywords :
computerised tomography; fault diagnosis; flip-chip devices; 2D X-ray image; 3D X-ray image; CT X-ray; computed tomography; device miniaturization; flip-chip device; flip-chip packaging defect; nondestructive fault isolation; package complexity; package integration; real-time X-ray; saturation point; shrinking package dimension; Conferences; Decision support systems; Electronics packaging;
Conference_Titel :
Electronics Packaging Technology Conference (EPTC), 2012 IEEE 14th
Conference_Location :
Singapore
Print_ISBN :
978-1-4673-4553-8
Electronic_ISBN :
978-1-4673-4551-4
DOI :
10.1109/EPTC.2012.6507140