DocumentCode
2035032
Title
Practical measure of cable coupling
Author
Thomas, D.W.P. ; Christopoulos, C. ; Leferink, F. ; Bergsma, H.
Author_Institution
GGIEMR, Univ. of Nottingham, Nottingham, UK
fYear
2009
fDate
14-18 Sept. 2009
Firstpage
803
Lastpage
806
Abstract
In this paper the crosstalk between two parallel coaxial cables is investigated. It is shown that the degree of coupling is strongly effected by the geometry of the system. In many practical situations the geometry of the cable routing is ill-defined so that an exact deterministic solution is not possible or helpful. A simple solution based on the first resonant frequency is proposed which can also be used to provide some statistical analysis of the possible degree of cable coupling.
Keywords
coaxial cables; statistical analysis; cable coupling measurement; crosstalk; parallel coaxial cables; resonant frequency; statistical analysis; Admittance; Cable shielding; Coaxial cables; Connectors; Coupling circuits; Electromagnetic compatibility; Geometry; Impedance measurement; Resonance; Resonant frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetics in Advanced Applications, 2009. ICEAA '09. International Conference on
Conference_Location
Torino
Print_ISBN
978-1-4244-3385-8
Electronic_ISBN
978-1-4244-3386-5
Type
conf
DOI
10.1109/ICEAA.2009.5297315
Filename
5297315