    Limitations on water cooling of rotors and stators in intermittent duty machines

  • Author

    Hearn, Clay S. ; Hahne, Jonathan J. ; Hebner, Robert E.

  • Author_Institution
    Texas Univ., Austin, TX, USA
  • fYear
    2004
  • fDate
    17-20 Oct. 2004
  • Firstpage
    696
  • Lastpage
    699
  • Abstract
    This investigation focuses on charge transfer and standoff considerations for a water coolant, where the water is in intimate contact with energized conductors. The flow rates of interest are up to 5 m/s. The emphasis is on the behavior of the coolant in intermittent duty machines in which the conductors are energized for periods of 10-5 to 10-3 s. As the water is routed through copper coolant tubes, the primary contaminant produced is copper.
  • Keywords
    charge exchange; contamination; coolants; cooling; copper; electric machines; electrical conductivity; rotors; static electrification; stators; 10-5 to 10-3 s; 5 m/s; Cu; charge transfer; copper concentration; copper contamination; copper coolant tubes; electrical conductivity; energized conductors; flow electrification; flow rate; intermittent duty machines; pulsed rotating machines; rotors; stators; streaming electrification; water coolant standoff considerations; water cooling limitations; Coils; Conducting materials; Conductors; Coolants; Cooling; Copper; Rotors; Stators; Thermal conductivity; Voltage;