• DocumentCode
    2036746
  • Title

    Development of VRLA battery for engine starters and its deterioration detection unit for high reliable telecommunications power system

  • Author

    Tsujikawa, Tomonobu ; Yabuta, Kaho ; Matsushita, Takashi ; Muroyama, Seiichi

  • Author_Institution
    NTT Facilities Inc.
  • fYear
    2005
  • fDate
    Sept. 2005
  • Firstpage
    181
  • Lastpage
    186
  • Abstract
    We have developed a VRLA battery (12 V- 65 Ah) for engine starters and a unit to detect deterioration. This battery can be used to start engine generators for telecommunications and ship engines. A capacity improvement of 14 to 67% has been achieved at a current discharge from 1 to 3 CA compared with the present battery by improving the positive grid and welding between cells. Consequently, we could reduce the battery volume for a ship engine by 40% compared with the present battery. The deterioration detection unit offers three functions, which are lifetime detection, voltage monitoring, and an external alarm, enabling the amount of maintenance required to be greatly reduced. We were able to collect and evaluate field-developed batteries that had been used for about five years to start ship engines. Consequently, we confirmed that they could be used continuously
  • Keywords
    engines; lead acid batteries; power system reliability; starting; telecommunication power supplies; VRLA battery; deterioration detection unit; engine generators; engine starters; ship engines; telecommunication engines; telecommunication power system reliability; voltage monitoring; Batteries; Corrosion; Engines; Marine vehicles; Monitoring; Petroleum; Power system reliability; Shape; Voltage; Welding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Conference, 2005. INTELEC '05. Twenty-Seventh International
  • Conference_Location
    Berlin
  • Print_ISBN
    978-3-8007-2905-0
  • Type

    conf

  • DOI
    10.1109/INTLEC.2005.335089
  • Filename
    4134328